Technical Parameters
Ø Working Pressure:16 Bar (For Air Blown Fiber System)
Ø Working Temperature: -20℃~+50℃
Ø Fluid: Compressed Air
Ø Lifespan:20 Years
Ø Standards: EN50411-2-8
Material
Ø Body: Polycarbonate
Ø Seal: NBR
Ø Washer: Polyacetal
Ø Lock Claws: SUS
Ø Collar: Polyacetal
Ø Sleeve: Polyacetal
Notes
Ø Please confirm the microduct outer diameter whether has damaged or scratches, connection face must be clean.
Ø Please confirm the microduct outer diameter nominal tolerances meets±0.1 mm.
Ø Please make sure the connection micro duct end face is cut into rectangular plane.
Ø Please confirm the microduct should be through the sealing ring, have been pushed to the end of the joint, until it couldn't go far again.
Ø After connecting the microducts, must check whether the duct can pull, then put into use.
Ø When disassemble the microducts, please make sure the pressure is 0.
Description
Ø Connect two microducts which are different outer-diameter
Ø Internal cone hole to prevent fiber hang up
Ø Easy installation, without any special tools
Ø Transparent plastic body, easy to observe the situation
Ø High temperature resistance -40℃~65℃
Ø High pressure resistance>25bar
Ø Standard EN50411-2-8
Specification | Duct OD/ID (mm) | Duct OD/ID (mm) | Taper Hole(mm) | PCS/CTN |
KPMRE10-7/5.5 | 10/8 | 7/5.5 | 8>5.5 | 1000 |
KPMRE10-8/6 | 10/8 | 8/6 | 8>6 | 1000 |
KPMRE12-7/5.5 | 12/10 | 7/5.5 | 10>5.5 | 800 |
KPMRE12-8/6 | 12/10 | 8/6 | 10>6 | 800 |
KPMRE12-10/8 | 12/10 | 10/8 | 10>8 | 800 |
KPMRE12.7-12/10 | 12.7/10 | 12/10 | 10 | 600 |
KPMRE14-12/10 | 14/10 | 14/10 | 10 | 600 |
Technical Parameters
Ø Working Pressure:16 Bar (For Air Blown Fiber System)
Ø Working Temperature: -20℃~+50℃
Ø Fluid: Compressed Air
Ø Lifespan:20 Years
Ø Standards: EN50411-2-8
Material
Ø Body: Polycarbonate
Ø Seal: NBR
Ø Washer: Polyacetal
Ø Lock Claws: SUS
Ø Collar: Polyacetal
Ø Sleeve: Polyacetal
Notes
Ø Please confirm the microduct outer diameter whether has damaged or scratches, connection face must be clean.
Ø Please confirm the microduct outer diameter nominal tolerances meets±0.1 mm.
Ø Please make sure the connection micro duct end face is cut into rectangular plane.
Ø Please confirm the microduct should be through the sealing ring, have been pushed to the end of the joint, until it couldn't go far again.
Ø After connecting the microducts, must check whether the duct can pull, then put into use.
Ø When disassemble the microducts, please make sure the pressure is 0.
Description
Ø Connect two microducts which are different outer-diameter
Ø Internal cone hole to prevent fiber hang up
Ø Easy installation, without any special tools
Ø Transparent plastic body, easy to observe the situation
Ø High temperature resistance -40℃~65℃
Ø High pressure resistance>25bar
Ø Standard EN50411-2-8
Specification | Duct OD/ID (mm) | Duct OD/ID (mm) | Taper Hole(mm) | PCS/CTN |
KPMRE10-7/5.5 | 10/8 | 7/5.5 | 8>5.5 | 1000 |
KPMRE10-8/6 | 10/8 | 8/6 | 8>6 | 1000 |
KPMRE12-7/5.5 | 12/10 | 7/5.5 | 10>5.5 | 800 |
KPMRE12-8/6 | 12/10 | 8/6 | 10>6 | 800 |
KPMRE12-10/8 | 12/10 | 10/8 | 10>8 | 800 |
KPMRE12.7-12/10 | 12.7/10 | 12/10 | 10 | 600 |
KPMRE14-12/10 | 14/10 | 14/10 | 10 | 600 |