Technical Parameters
Ø Working Pressure:16 Bar (For Air Blown Fiber System)
Ø Working Temperature: -20℃~+50℃
Ø Fluid: Compressed Air
Ø Lifespan:20 Years
Ø Standards: EN50411-2-8
Material
Ø Body: Polycarbonate
Ø Seal: NBR
Ø Washer: Polyacetal
Ø Lock Claws: SUS
Ø Collar: Polyacetal
Ø Sleeve: Polyacetal
Notes
Ø Please confirm the microduct outer diameter whether has damaged or scratches, connection face must be clean.
Ø Please confirm the microduct outer diameter nominal tolerances meets±0.1 mm.
Ø Please make sure the connection micro duct end face is cut into rectangular plane.
Ø Please confirm the microduct should be through the sealing ring, have been pushed to the end of the joint, until it couldn't go far again.
Ø After connecting the microducts, must check whether the duct can pull, then put into use.
Ø When disassemble the microducts, please make sure the pressure is 0.
Description
Ø Used to seal a open microduct
Ø Easy installation, without any special tools
Ø Transparent plastic body, easy to observe the situation
Ø High temperature resistance -40℃~65℃
Ø Standard EN50411-2-8
Specification | Duct OD (mm) | PCS/Bag | Specification | Duct OD (mm) | PCS/Bag |
KPEST3 | 3 | 6000 | EST12 | 12 | 2000 |
KPEST4 | 4 | 5000 | EST12.7 | 12.7 | 2000 |
KPEST5 | 5 | 5000 | EST14 | 14 | 1600 |
KPEST6 | 6 | 4000 | EST15 | 15 | 1000 |
KPEST7 | 7 | 4000 | EST16 | 16 | 1000 |
KPEST8 | 8 | 4000 | EST18 | 18 | 800 |
KPEST10 | 10 | 2000 |
Technical Parameters
Ø Working Pressure:16 Bar (For Air Blown Fiber System)
Ø Working Temperature: -20℃~+50℃
Ø Fluid: Compressed Air
Ø Lifespan:20 Years
Ø Standards: EN50411-2-8
Material
Ø Body: Polycarbonate
Ø Seal: NBR
Ø Washer: Polyacetal
Ø Lock Claws: SUS
Ø Collar: Polyacetal
Ø Sleeve: Polyacetal
Notes
Ø Please confirm the microduct outer diameter whether has damaged or scratches, connection face must be clean.
Ø Please confirm the microduct outer diameter nominal tolerances meets±0.1 mm.
Ø Please make sure the connection micro duct end face is cut into rectangular plane.
Ø Please confirm the microduct should be through the sealing ring, have been pushed to the end of the joint, until it couldn't go far again.
Ø After connecting the microducts, must check whether the duct can pull, then put into use.
Ø When disassemble the microducts, please make sure the pressure is 0.
Description
Ø Used to seal a open microduct
Ø Easy installation, without any special tools
Ø Transparent plastic body, easy to observe the situation
Ø High temperature resistance -40℃~65℃
Ø Standard EN50411-2-8
Specification | Duct OD (mm) | PCS/Bag | Specification | Duct OD (mm) | PCS/Bag |
KPEST3 | 3 | 6000 | EST12 | 12 | 2000 |
KPEST4 | 4 | 5000 | EST12.7 | 12.7 | 2000 |
KPEST5 | 5 | 5000 | EST14 | 14 | 1600 |
KPEST6 | 6 | 4000 | EST15 | 15 | 1000 |
KPEST7 | 7 | 4000 | EST16 | 16 | 1000 |
KPEST8 | 8 | 4000 | EST18 | 18 | 800 |
KPEST10 | 10 | 2000 |